Formula and method
Worked example
36 AWG has a defined diameter of 0.005 in = 0.127 mm and a circular area of approximately 0.012668 mm².
Assumptions and limits
- Results are mathematical nominal dimensions for a round solid bare conductor. Standards tables may round diameters, and manufacturing tolerances cause further variation.
- This conversion does not determine ampacity, voltage drop, temperature rise, insulation diameter or stranded-bundle diameter, and does not select an equivalent IEC nominal cross-section.
- The supported range is discrete 4/0, 3/0, 2/0, 1/0 and 1–40 AWG. Rounding the area does not establish a compliant cable size.
Frequently asked questions
Why is 4/0 thicker than 1 AWG?
AWG numbers increase as conductors get thinner. The successive sizes thicker than 1 are 0, 00, 000 and 0000, also written 1/0 through 4/0.
Can I size a fuse or circuit breaker from this result?
Cross-sectional area alone is insufficient. Check conductor material, insulation temperature rating, installation method, grouping, ambient conditions and the applicable electrical code.